retrofiting specification for a wood deck

Building In-Home Retrofit Shelters for Existing Houses specifications for the retrofit room developed are based on the known performance and strengths of Florida Building Code debris testing specifications for materials . #6x1-1/2” Wood. Deck Screws. #8x3” Wood. Deck Screws. #6x1” Wood. Deck Screws. First layer of plywood. 3” o.c. edges. 6” o.c. in field. Second layer.

OMG Roofing Products: Fastening Solutions for Roofing - Retrofit OMG supplies roofing fasteners for the roofing industry, as well as pipe supports, insulation adhesives, retrofit roof drains and construction accessories. We are there when you need us, so give us a call today.

residential decks - City of Burnsville Building Permits: A permit is required if the deck is attached to the dwelling, is 30” (or more) off the ground, or is dead load (wood, decking, etc.) SPECIFICATIONS. R602.3 SPLIT BEAM ATTACHMENT TO POSTS IS NOT ACCEPTABLE AND WILL. REQUIRE ADDITIONAL MEANS OF SUPPORT FOR THE BEAM. 6-1/2

Simpson Strong-Tie Retrofit ZMAX Galvanized Steel Post Base Strongly secures and reinforces deck posts; Constructed of 12-gauge steel for strength and durability; Corrosion resistance makes it great for outdoor applications conditions in many environments; Made from 12-Gauge steel; ZMAX galvanization offers extra corrosion resistance for exterior and treated-wood applications

Building a Code-Compliant Deck - Extreme How To Jul 13, 2015 Pro Tips on Building a Code-Compliant Deck. Joist Span. When choosing deck lumber based on joist span, I use the following easy-to-remember rule of thumb that works for most of the treated wood species that. I use for building . There are a few retrofit options available to accomplish the post to beam.

Deck Framing Connection Guide - Sussex County specifications and Simpson Strong-Tie connectors are properly installed in accordance with applicable building Existing Decks: Retrofit or Replace. 6 Improper deck building has resulted in a growing number of deck failures and related injuries and deaths. According to Don Bender, the director of the Wood Materials.

deck construction specifications - Lancaster, OH (740) 687-6649, Fax (740) 681-5030. Web site: www.ci.lancaster.oh.us/dept/building. DECK CONSTRUCTION. SPECIFICATIONS. ACCORDING TO I.R.C. 2000 Joists framing into the side of a wood girder shall be supported by approved framing anchors or on FIGURE 1: JOIST SPAN - DECK ATTACHED AT HOUSE.

Deck Framing Connection Guide - Tulalip Tribes Simpson Strong-Tie products will perform in accordance with the specifications set forth in the . deck, it may be preferable to retrofit it by applying hardware to existing . 2" nominal deck ledger shown. (double 2" ledger similar). SDWS or SDWH wood screws. Band joist. Wood structural panel sheathing. 1?2" max. thickness.

Wood Decking Technical Specifications - CMD Group Download Technical datasheets and 3 part specifications for Wood Decking with SmartBuilding Index, the resource construction industry professionals rely on to help with critical decision-making (CSI MasferFormat Division 06 15 00)

Retrofitting Railroad Bridges for Recreation Wheeler Deck Conversion Made Simple Using prefabricated treated timber deck panels, Wheeler has designs to retrofit any existing railroad bridge. Panel dimensions are customized to provide the desired trail width, typically ten or twelve feet. The thickness varies from four to eight inches based on existing conditions and.

DeckLok? Advanced Lateral Anchor Deck Bracket System! - Star Meets IBC requirement of 500lbs of force; Ensures secure connection between deck and stairs; Eliminates deck pullout; Inexpensive: replaces second beam, columns and footings; Easy to install deck bracket; Works in both new construction and retrofit; Helps avoid personal injuries (and lawsuits) from stair collapse

Wood Decking - Alberta Infrastructure .3 Specification Section Text: 1. General. 1.1 Related Work specified In other Sections. 1.2 Product Options and Substitutions. 1.3 Reference Documents. 1.4 Submittals. 1.5 Quality Assurance. 1.6 Delivery Storage and Handling. 2. Products. 2.1 Description. 2.2 Materials. 2.3 Accessories. 2.4 Wood Treatment. 3. Execution.

USG Structural Panel Concrete Roof Deck Submittal Sheet (English For retrofit or renovation projects, USG Structural Panel Concrete Roof Decks can also be installed on wood-joists and hot- rolled steel framing. See recommended fasteners within this Structural Panel Concrete Roof Decks must be installed according to USG specifications, using only the listed materials and components.

Residential Wood Deck Design - American Wood Council To encourage compliant deck design and construction, American Wood Council (AWC) has published Design for Residential Wood. Deck Design updates and discussions on structural specifications. STRUCTURAL. SPECIFICATIONS. According to recent industry reports, 6,500 retrofit activities related to residential

STRUCTURE magazine Residential Wood Deck Design They may also be involved in inspection and retrofit activities related to residential wood decks. DCA 6 applies to single level residential wood decks only. Multi-level and designed to resist lateral load conditions, the post would need to be designed per the National Design Specification? (NDS?) for Wood Construction.

Deck Framing Connection Guide - The Home Depot Simpson Strong-Tie catalog specifications and Simpson Strong-Tie connectors are properly installed in Improper deck building has resulted in a growing number of deck failures and related injuries and deaths. According to Don Bender, the director of the Wood Materials . be suitable for deck retrofit. Selection of

1 HURRICANE MITIGATION RETROFITS FOR EXISTING SITE (a) Roof-decking attachment and fasteners shall be strengthened and corrected as required by section 201.1. 101.4 When retrofit enhancement of gable end bracing is provided during construction which otherwise requires .. using fasteners consistent with the bracket manufacturer's specifications for wood connections

Residential Wood Deck Construction Guide Other Communities Decking shall be wood 2x4, 2x6, five quarter board, or Wood-Plastic Composite sizes per the manufacturer's specifications. ? Wood decking shall be attached as shown in Figure 1. Decking should also be attached to the rim board with fasteners at 6” O.C.. ? Each wood decking member must rest on three joists minimum.